- Abbott has launched 2 molecular tests under the u.s. Food and drug administration emergency use authorization (eua) to run on the Alinity m and m2000 system. The ID NOW™ COVID-19 rapid point-of-care test. The ID NOW™ COVID-19 assay is available under U.S.
- The Abbott Architect System is a fully automated random access analyser that utilizes a chemiluminescent microparticle immunoassay (CMIA) technology with flexible assay protocols, refer to as Chemflex®. Section: Serology Procedures Subject Title: Architect Manual ’.
Sep 03, 2020 ABBOTT ARCHITECT 1000 MANUAL OTOMOTIFPARTS COM. ABBOTT ARCHITECT 1000SR TMOLLY DE. WANTED ABBOTT LABS ARCHITECT I 1000SR DOTMED. CONTACT US GUNJANLAB clinical endocrinology – doctors center may 7th, 2018 - 1 architect i 1000sr from abbott diagnostic an immunoassay analyzer used for precise and high quality testing for a. Abbott Architect C8000 Manual.pdf - Free Download Abbott Architect C8000 Manual The ARCHITECT c8000 offers a maximum throughput of up to 1,200 tests per hour. Featuring a load-up capacity of 215 samples with 35 priority positions, the ARCHITECT c8000 has up to 121 refrigerated reagent positions plus Integrated Chip Technology (Na+, K+ and Cl.
Abbott Architect 1000 Manual Instructions
ARCHITECT- i1000SR
tde ARCHITECT i1000SR Immunoassay Analyzer meets your laboratory's high standards by delivering STAT results when you need tdem. tde advanced technology and flexible protocols built into tde ARCHITECT i1000SR enhance laboratory workflow and allow you to report results witd confidence.
![Architect Architect](https://i.ytimg.com/vi/T1K1LRpamrE/hqdefault.jpg)
SPECIFICATIONS | DESCRIPTIONS |
---|---|
Metdods | CHEMIFLEX |
Maximum troughput | Up to 100 tests/hour |
Sample Types | Serum, Plasma, Whole Blood, Urine |
Sample Tubes | Height: 72-102 mm Diameter: 9.6 -16.1 mm |
Sample Cup | Yes (50 µl dead volume) |
Sample Capacity | 65 |
Sample Barcode Types | Code 39, Codabar, Interleaved 2 of 5, Code 128 |
Sample Result Storage | 50,000 |
Sample Volume | 10-150 μL, Average: 50 µL |
Automatic Dilution | Yes |
Sample Probe Carryover | <0.1 parts per million |
Reagent Capacity | 25 refrigerated positions |
Reagent Type | 100% liquid ready-to-use liquid reagents |
Reagent Onboard Stability | Majority of assays are stable on board 30 days |
Calibration Frequency | Calibrate witd new lot number,controls are specified otderwise |
Sample Clot and Bubble Detection | Yes |
Reagent Pressure Monitoring | Yes |
Sample Interference Measurement | No |
System Control Center | 1 SCC, witd color touchscreen , keyboard, and mouse |
On-board Maintenance Records | Yes |
Online Error Code Help | Yes |
Host Interface | Bidirectional, serial RS-232 interface, query option available |
Remote Diagnostics | AbbottLink® |
Dimensions (HxWxD) | 49” x 59” x 30” 124.5 x 149.9 x 76.2 cm |
Weight | 636 lb 288 kg |
Electrical Requirements | AC 110-240V±10%, 47-63 Hz |
Water Requirements | Purified water to dilute buffer concentrate |
Heat Output | 2400 BTU/hr, Running Mode |
One moment please..
Not A Member?Sign Up
- Videos
- News
DESCRIPTION
The ARCHITECT i1000SR analyzer is the newest immunoassay member of the ARCHITECT Family of Instruments, sharing all the proven benefits of other members of the Family.
Abbott Architect 1000 Manual Download
![Abbott architect 1000 manual online Abbott architect 1000 manual online](https://image.slidesharecdn.com/architecti1000sr-guiadecapacitacionusuario-abbott-190325154757/95/architect-i1000sr-guia-de-capacitacion-usuario-abbott-39-638.jpg?cb=1553529795)
The ARCHITECT i1000SR is uniquely designed for lower - mid volume laboratories and for integration with the c4000 chemistry analyzer. The i1000SR offers labs the agility to free them from their everyday workload issues.
FORUMSView All (7)
Ask a New Question1Reply4 months ago | 4 months agohow to troubleshoot error always occur.after the machine is turned on.after how many minutes, eooer appear: unable to communicate or the 0300 code error. how to solve? do i need to buy another switch hub? thank youReply |
-Baje33 10 months ago | 10 months agoService Manual Does any one have a service manual for The Abbott ARCHITECT i1000SR analyzer?Reply |
0Replies4 years ago | 4 years agoWater consumption per hour How high is the water consumption for the Abbott i1000 per hour? Reply |
DOCUMENTS / MANUALSView All
FEATURES
Streamlined workload management
Abbott Architect 1000 Manual Pdf
- Continuous access to reagents, samples and supplies
- 65 sample load capacity
- 25 refrigerated reagent positions
- Reagents stable on board for up to 30 days (tracked in hours)
- Testing handled with ease
Fewer workload pauses Toshiba e studio 263 cs driver.
- Simple and easy to use system with intuitive ARCHITECT software
- Low maintenance (10 minutes/day)
STATs prioritized fast
Abbott Architect 1000 Manual Free
- Immediate and consistent STAT processing with turnaround time of 15.6 minutes on STAT assays
- Automatically runs priority tests first with up to 7 customizable priority bays or 35